The former algorithms, such as pencil beam convolution pbc algorithm with 1d or 3d density correction methods, overestimated the tcp while underestimating ntcp for lung cancer. Basically, for scanned beams elemental pencil beam models and ray casting techniques are used see, e. A pencil beam algorithm for proton dose calculations. A pencil beam algorithm for helium ion beam therapy. The pencil beam algorithm described by hogstrom et al. Aaa photon dose calculation model in eclipsetm citeseerx. A comprehensive methodology for proton pencil beam crossing titanium implants. The aaa dose calculation model is a 3d pencil beam convolutionsuperposition algorithm that.
Model based dose calculation algorithms in external. Comparison of pencil beam, collapsed cone and montecarlo. Dosimetric evaluation of a pencil beam algorithm for electrons employing a twodimensional heterogeneity correction. First, the experiments were designed to verify the local beam database and some fundamental characteristics of the electron beam calculations. Intensity modulated dose calculation with an improved. The concept of redefinition was first used for both fixed and arced electron beams by hogstrom et al. Recently, a finite size pencil beam fspb algorithm, based on a simple and small set of data, was proposed which was specifically.
Purpose fast energy switching is of fundamental importance to implement motion mitigation techniques in pencil beam scanning proton therapy. A pencil beam model for photon dose calculation ahnesjo. For this purpose we developed a new highly efficient version of a pencil beam convolution algorithm originally devised in ref. The pencil beam algorithm in tms the core of a pencil beam algorithm for electron dose calculation can be divided into two main parts. Eclipses pencil beam algorithm, does not take into account secondary electron transport, but pinnacles collapsed cone convolution algorithm, or the monte carlo method, both of which that do. The impact of dose calculation algorithms on partial and. Pdf calculation of a pencil beam kernel from measured photon. Wed like to understand how you use our websites in order to improve them. Varian medical systems barbara schaffner, ptcog 46 slide 4 broad beam algorithm concept find the range and the modulation of the beam required to cover the target find the depth and the distance to the aperture for each point of interest poi use lookup tables for the dose in depth and apply a correction for the lateral penumbra.
Fast pencil beam dose calculation for proton therapy using. Iaea 2004 absorbed dose determination in external beam radiotherapy. Evaluation of the raycasting analytical algorithm for. A 3d pencil beam based superposition algorithm for photon dose calculation in heterogeneous media article pdf available in physics in medicine and biology 5314. Source model accurate characterization of therapeutic photon beams requires the modeling of different radiation sources in the linear accelerator. Here we present an extension to the dose calculation engine employing a doublegaussian beam model to. Pb plans of 60 avm patients who were already treated using 6 mv photons from a linear.
Pencil beam algorithms are unsuitable for proton dose. A finite size pencil beam algorithm for imrt dose optimization. The transverse profiles of pencil beams are often represented by gaussian functions in order to speed up electron beam treatment planning algorithms, because. Proton dose calculation algorithms and configuration data. Pencil beam algorithms are common for electron beam dose calculations. In this thesis, a dose calculation method based on the superposition of monte carlo simulated pencil beam kernels was developed. A triple gaussian pencil beam model for photon beam treatment. Pdf in this work, a novel threedimensional superposition algorithm for photon dose calculation is presented.
Predictions of the algorithm and results from experiments performed in a large. A new photon dose calculation model, the analytical anisotropic algorithm. Pdf dosimetric evaluation of a pencilbeam algorithm for. Overestimation of dose in the lung by up to 14%, 14, 15 has been observed with simple analytic algorithms eg, pencil beam because they fail to properly account for lateral scatter and loss of electronic equilibrium. The pencil beam algorithm developed for helium ions presents a suitable tool for dose calculations. D treatment planning that is general enough to handle irregularly shaped radiation fields incident on a heterogeneous patient. Since most of the actual desktop computers provide more than one calculation core we used multithreading extensively to parallelize the workload and thus speedup the algorithmic runtime. Planning target volume dose distribution dose calculation pencil beam primary photon. Test procedures for verification of an electron pencil beam algorithm. Development of an optimized pencil beam algorithm for.
An international code of practice for dosimetry based. The pencil beam is divided into a depthdirected and a lateral component, which are separately scaled. Pdf a 3d pencilbeam based superposition algorithm for photon. A predictive algorithm for spot position corrections after fast energy switching in proton pencil beam scanning. We have previously described an implementation of a pencil beam algorithm running on graphics processing units gpus intended specifically for online dose calculation. The model includes a new approach to picking the locations of the pencil beams so as to. The feasibility of magnetic resonance image mri based proton therapy is based, among several other factors, on the implementation of. Pdf usually, pencil beam kernels for photon beam calculations are obtained by monte carlo calculations. Pdf a pencil beam algorithm for magnetic resonance image. It assumes that any collimated photon beam hitting incident on the patient is actually a conglomeration of lots of smaller, narrow pencil beams. Test procedures for verification of an electron pencil. A pencil beam algorithm for intensity modulated proton. Figure 1 shows an example of an initial photon spectrum for a 6 mv. The source model for the open beam consists of a primary.
Pdf modeling of beam customization devices in the pencil. The pencil beam algorithm is dose calculation technique. We have developed a pencil beam algorithm for proton dose calculations which takes accurate account of the effects of materials upstream of the patient and of the air gap between them and the patient. Monte carlo mc and pencil beam pb algorithms in srssrt plans of cranial arteriovenous malformations avms. In radiotherapy treatment, the calculation of radiation dose distribution in target volume lead to an optimum set of planning parameters. A method for photon dose calculation in radio therapy planning using pencil beam energy deposition kernels is presented. Here we use a multiplesource model developed by the authors tillikainen etal2007. Each of these pencil beams has a central axis ray along which it deposits some dose. Pdf clinical comparison of pencil beam convolution and. The beam splitting method is reasonably accurate, efficient, and general so that it can be potentially used in various pencil beam algorithms. The pencil beam algorithm and the broad beam version are both fully implemented into a treatment planning system. Pencil beams model eclipse uses pencil beams extracted from measurements spb or from monte carlo calculation aaa heterogeneities handled via effective path length longitudinal aaa adds a scaling of the spread of the pencil based on density lateral aaa also have an extensive beam modelling analytical anisotropic algorithm.
The flexible design allows easy customization of measured depth. Scholz c, nill s, oelfke u 2003a comparison of imrt optimization based on a pencil beam and a superposition algorithm. Pdf a 3d pencilbeambased superposition algorithm for. A gpubased finitesize pencil beam algorithm with 3d. Optimization of extracranial stereotactic radiation. Pencilbeam redefinition algorithm for electron dose. Optimization of geant4 settings for proton pencil beam. Pdf a 3d pencilbeam based superposition algorithm for.
Accurate proton treatment planning for pencil beam. A method of scaling the 3d electron pencilbeam dose. This worked has been aimed to compare two photon beam dose calculation algorithms in the oncentra treatment. This study is a retrospective dosimetric comparison of iplan. A total of five breast and five lung cases were calculated using the pb, cc, and mc algorithms. The accuracy of the dose calculation depends on the treatment planning algorithm. A predictive algorithm for spot position corrections after. Modeling of beam customization devices in the pencil beam splitting algorithm for heavy charged particle radiotherapy. Difference between pencil beam algorithm and collapsed cone convolution algorithm for. An additional application of the pencil beam algorithm is as an independent system for checking treatment.
For this reason, pencil beam algorithms are no longer allowed on clinical trials for lung treatment with photon therapy. In imrt planning, the pencil beam approach is normally used during the optimization process, as well as for the. Its calculation speed was evaluated to be similar to other published pencil beam algorithms. Comparison of pencil beam, collapsed cone and monte carlo. Comparison of dose calculations between pencilbeam and. Dose calculation algorithms play a central role for the clinical practice of radiation therapy. Evaluation of the computation dose engine, comparing pencil beam vs montecarlo algorithms.
Experimental determination and verification of the parameters used in a proton pencil beam algorithm. The dose calculation is performed as a superposition of pencil beams, which are modified based on. Effects of artefacts on ct images and their reduction by a dedicated algorithm. A pencil beam redefinition algorithm has been developed for the calculation of electron beam dose distributions on a threedimensional grid utilizing 3d inhomogeneity correction. Dose calcualtion algorithms in 3dcrt and imrt 20080727. Comparison of pencilbeam, collapsedcone and montecarlo. A fast finite size pencil beam algorithm for dose calculation using gpus introduction fast and accurate dose calculation is a primary requirement for online adaptive radiotherapy. The concept of redefinition was first used for both fixed and arced electron beams by hogstrom e t a l. To have a phantomindependent beam calibration and avoid specifying the dose per mu to a point in the dose distribution, it becomes necessary to utilize more of the predictive behavior of the pencil beam algorithm. A gpubased pencil beam algorithm for dose calculations in proton radiation therapy article pdf available in computer and information science 6144 september 2015 with 263 reads. A standardized commissioning framework of monte carlo dose. A 3d pencilbeam based superposition algorithm for photon dose calculation in heterogeneous media. It is designed to meet the requirements of an algorithm for 3. It is therefore very important to rely on development of a fast and accurate dose calculation algorithm.
795 1571 1578 533 772 407 444 229 1514 1078 722 117 52 489 1268 37 836 1271 1229 1276 716 830 1106 676 702 459 1500 841 291 348 1081 940 1107 1088 25 573 103 437 1419